Skip to main content

Wire Labels

How to run and use the Wire Labels Report

A
Written by Ashok P
Updated over a month ago

The Wire Labels report is used to create wire labels for the wire connections in Visio and AutoCAD. This report is intended to be used with schematic drawings.

  • In Visio, any SI shape connected with an SI wire shape will generate data for these reports.

  • In AutoCAD, only schematic blocks and schematic wire blocks generate data for this report.

Wire Label Report Variations

There are three variations of the Wire Checklist report.

wire labels in list.jpg

Wire Labels By Head End

The labels from this report display Head End, From Device (Component ID,) To Location, and Wire (Component ID.)

The labels do not display any I/O fields from schematic connections.

by head end.jpg

Wire Labels By Location

The labels from this report display Wire Location, From Device (Component ID,) To Device (Component ID,) and Wire (Component ID.)

The labels do not display any I/O fields from schematic connections.

by location.jpg

Wire Labels By Wire Number

The labels from this report display Device (Component ID) - (Label,) To Device (Component ID) - (Label,) and Wire (Component ID).

by wire number.jpg

The label data for this report comes from the label of the I/O used on the schematic shape or block.

schematic labels.jpg

Label Sheets

The label sheets (Model LSL78 from Impact, Inc.) that these reports were designed to be used with are sheets of 7 columns with 3 rows (21 labels/sheet).

The text prints on a white part of the sticker and the rest of the sticker is clear for wrapping or protecting the text.

layout of sheet.jpg

Customizing the Wire Labels Report

You can customize this report to print wire labels using any other brand of labels that you prefer.

Check out this article for more details.

Did this answer your question?